Zeiss Visulas YAG II+ Laser

This Zeiss VISULAS Yag II Plus has been recently serviced, refurbished, and calibrated by our on-staff technicians. It is in great working and cosmetic condition.

Max energy: 10.8 mJ

Complete System Includes:

  • Factory table
  • Manual
  • Accessories

Specifications:

  • Type (Configuration): 4-point diode, 670 nm
  • Intensity regulation (Aiming Beam) 5-150 µW in 20 steps
  • Uses: Ophthalmic posterior capsulotomy
  • Energy selection: 10 levels
  • Shot selection: Yes
  • Power output: Actual metered
  • Additional Features: (Alarms, high/low) Accumulated energy, service messages
  • Calibration procedure (Interference compensation):Automatic
  • Slit lamp: Zeiss Delivery System
  • Power Requirements: 115/230
  • Nd:YAG BEAM Operating mode (DISPLAYS/CONTROLS) Q-switched

CARL ZEISS Visulas 532 Laser – Argon

Zeiss Visulas 532 Green Argon Laser w Integrated Slit Lamp & Factory Power Table

The Zeiss Visulas 532 Green Laser System comes completely integrated into a factory Zeiss slit lamp, fiber, console with remote and Zeiss factory power table. Fully refurbished, calibrated, and ready to go.

Excellent condition and very low use 532 green laser! We purchased this from the original owner who used the system sparingly over the years. The condition is excellent both mechanically and cosmetically. All functions are working and the laser energy is within 3% to 7% in all treatment ranges! These are excellent numbers for even a new laser. If you are looking for a low cost integrated solution 532nm green laser, this is it! Professional installation recommended, please contact us for a quote.

TUBE COMPOSITION

Voltage Vac: 115/230
Current, a: 8
Kva (POWER NEEDED): 600W maximum
WEIGHT, kg (lb) (DISPLAY): 37(81.4)
W x D, cm (in): 30x 44 (11.8 x 17.3)console
Type (CONFIGURATION): Frequency-doubled Nd:YAG

BEAM SPECIFICATIONS

Nd:YAG: 532
Nd:YAG: 1.2
AIMING BEAM TYPE: Red diode
WAVELENGTH: 670nm
Energy, mw (Delivered power, W): 0.1-1, 5 steps
DELIVERY MODES: Single, repeat, continuous wave
EXPOSURE TIME, sec (MICROMANIPULATORS): 0.01-2.5, continuous wave
Repeat time, sec (Delivered power, W): Up to 6 Hz, 10 steps
Spot diameter: 50-1,000 parfocal

DELIVERY SYSTEM

Slit lamp: Zeiss dedicated slit lamp based on SL-130
USES (STAINING POSTS): Retinal, peripheral, iridectomy, trabeculoplasty
OTHER SPECIFICATIONS (AIR SUPPLY): Switchable physician safety filter for slit lamps and surgical microscope; motorized micro- manipulator; diode-on-demand activates pumping diode only when footpedal is pressed; combined 532/Nd:YAG laser system (VISULAS Combi 532) available.
FDA CLEARANCE (Interference compensation): Yes

Zeiss Cirrus OCT Model 400

Thank you for viewing our listing! This Cirrus 400 has been completely serviced and refurbished by our trained staff of technicians. This unit comes with software, printer, power table and all peripherals as shown.

The world’s best-selling spectral domain OCT system is now offered in Model 400. What’s unique about Model 400? Focused on the essential core OCT functionality, Model 400 is designed with the smaller budget in mind. Live OCT Fundus technology provides the fundus image using the OCT scanner only, rather than an additional line scanning ophthalmoscope (LSO).

The 400 offers glaucoma and retina analyses and is capable of anterior segment imaging just like the 4000. The dense data cubes are interchangeable between model 400 and model 4000 systems. Cirrus HD-OCT models also share the same modern integrated design, ease of use, and small footprint.

Features

  • Macular Thickness Analysis
  • RNFL Thickness Analysis
  • Normative Database – RNFL
  • Advanced Visualization and 3D Display
  • Anterior Segment Imaging
  • 5-line Raster Scan
  • Compatible with Cirrus Review Software (license sold separately)

Includes

  • Fundus imaging
  • Scanning system Live OCT Fundus Technology
  • Field of view 36 x 22 degrees
  • OCT imaging
  • Methodology Spectral domain
  • Scan speed 27,000 A-scans / sec
  • A-scan depth 2.0 mm (in tissue)
  • Axial resolution 5 µm (in tissue)
  • Transverse resolution 15 µm (in tissue)

Computer

  • Processor Intel Pentium Core 2 Duo, Win XP OS
  • Memory 2GB
  • Hard Drive 750GB

Physical

  • Size 26L x 17W x 21H (in)
  • Table footprint 39L x 22W (in)

Zeiss Vistante OCT

Key Features

  • Provides excellent high-resolution images of the anterior segment of the eye
  • Uses low-coherence interferometry to produce cross-sectional tomographs of the cornea and anterior chamber
  • A non-contact instrument that captures its images quickly and with little technician effort
  • Extremely useful in determining residual stromal bed for the purposes of LASIK enhancement and monitoring cases of endothelial keratoplasty

Technical Specifications

  • Illumination laser source long wavelength 1,310 nm superluminescent LED Scan types
  • Anterior segment — Single, dual and quad line scans (16 mm x 6 mm) Adjustable in 1-degree increments 256 A scans per line sampling 0.125 second per line acquisition time
  • Pachymetry map — Adjustable 8-line scan pattern (10 mm x 3 mm) Regional map with maximum, minimum and average values 128 A scans per line sampling 0.5 second total acquisition time
  • High-resolution corneal scans Adjustable in 1-degree increments (10 mm x 3 mm) 512 A scans per line sampling 0.25 seconds per line acquisition time
  • Optical resolution Axial: 18 μm Transverse (center): 60 μm
  • Ametropia correction: -35 to +20 diopters
  • Fixation target: Internal or external
  • Display: Integrated 15-inch flat-panel display
  • Computer specs: Windows / 3.0 GHz Pentium IV / 1 GB memory

Dimensions/Weight

  • 48.5 cm H x 43.8 cm W x 63.2 cm D; 34.5 kg
  • (19.1 inch H x 17.2 inch W x 24.9 inch D) 76.1 lb

Zeiss Atlas 9000 Topographer

The Atlas 9000 is one of the best and most reliable topographers offered by Carl Zeiss. With its patented Cone-of-Focus Alignment System and Arc-Step Algorithm, the Atlas 9000 delivers sub-micron elevation accuracy. Using triangulation, the advanced ATLAS Arc-Step algorithm provides reliable surface reconstruction, 22-ring Placido disk optimized to avoid ring crossover, which means reliable results for a wide range of patients, and long, comfortable 70 mm working distance minimizes focusing error found in “small cone” systems.

Key Features

  • By merging proven ATLAS Placido disk technology with Visante OCT pachymetry, Visante Omni now provides comprehensive anterior and posterior topography.
  • Proven Placido Disk Technology with patented Cone-of-Focus™ Alignment System
  • SmartCapture™ Image Analysis Technology analyzes multiple images during alignment and automatically selects the highest quality image
  • MasterFit™ II Contact Lens Software helps streamline the fitting of gas permeable (GP) lenses and guides you through difficult and specialty fits
  • Data compatibility with previous generation ATLAS Corneal Topography Systems to facilitate data management and patient follow up
  • SmartCapture analyzes 15 digital images per second during alignment and automatically selects the highest quality image
  • Next generation image processing provides more repeatable, reliable results, even in difficult cases
  • Less dependence on operator technique means greater efficiency and fewer repeat exams
  • Corneal Wavefront Analysis takes corneal topography to a new dimension.
  • Using ray tracing technology, the ATLAS displays higher-order corneal aberrations, providing valuable insight for patient education and treatment planning.
  • Educate patients about higher-order aberrations and simulate visual acuity
  • Assess corneal refraction with image simulation and point spread function
  • Measure corneal spherical aberration with Zernike analysis to optimize the selection of aspheric IOLs
  • View the effects of individual higher order corneal aberrations
  • View changes in contrast sensitivity through the modulation transfer function (MTF)
  • Pupil size, measured at two levels of illumination (scotopic and photopic @700 nm), provides insight into optical zone under varying light conditions
  • View centration of LASIK or orthokeratology treatment in relation to pupil center to assess treatment effectiveness
  • Improve multi-focal contact lenses selection by understanding patient’s pupil size at two levels of illumination
  • Streamline contact lens selection and fitting with automatic Horizontal Visible Iris Diameter (HVID) meCompact, integrated system with powerful computer and analysis software
  • Unique chin rest positions patient for easy image capture and wide peripheral coverage and automatically detects OD/OS
  • Non-visible Placido ring illumination is comfortable for even the most light-sensitive patients

Working Distance: 70 mm

Field of View: 17 mm X 14.5 mm

Placido Rings: 22 (18 superiorly, 22 inferiorly)

Illumination Source: Non-visible infrared (950 nm) LED

Optics: Digital CMOS camera with 1280×1024 pixel resolution

Curvature

  • Measurement Range: 15 to 95 D (3.5 to 22.5 mm)
  • Accuracy: ± 0.05 D (± 0.01 mm)
  • Reproducibility: ± 0.10 D (± 0.02 mm)

HVID (white to white)

  • Measurement Range: 10.0 to 14.0 mm
  • Resolution: 0.1 mm

Pupillometry

  • Acquired Images: Scotopic and photopic (700 nm)
  • Measurement Range: 0.5 to 11.0 mm
  • Resolution: 0.1 mm

Views

  • Axial Curvature
  • Tangential Curvature
  • Elevation (Best-Fit Sphere)
  • Irregularity (Best-Fit Ellipsoid)
  • Videokeratoscopic (Rings, Scotopic, Photopic)
  • Keratometry
  • Refractive Power
  • Mean Curvature
  • Corneal Wavefront
  • Image Simulation
  • Point Spread Function (PSF)
  • Modulation Transfer Function (MTF)

Presentation Displays

  • Single View
  • Overview
  • OD/OS Comparison
  • Difference
  • Trend with Time
  • Custom

Dimensions/Weight

  • 52 L x 37 W x 50 H (cm)
  • 39 lbs. (17.7 kg)

Electrical: 100-240V~: 50/60Hz, 2-1A