Carl Zeiss IOL Master Version 500 w New Printer & Calibration Test Eye

Zeiss IOL Master Version 500 with Printer and Test Eye Included (no table) 
 
This unit has been fully tested, serviced, and refurbished at our headquarters in Tampa, Florida. We also include a full warranty.   Note that the factory power table is not included, but available for an additional cost (see other listings).  Shipping is fast and free!
 
Our trained technicians have tested and serviced this IOL 500 to ensure it is operating to the manufacturer’s specifications. The Zeiss system software is version 7.7 and the Holladay 2 Software is also active.     

The system is complete with the factory calibration test eye, new printer, operator’s manual, dust cover and peripherals.  

Please feel free to contact us at any time for further information on this IOL 500. We ship to over 100 countries, the system is in stock here at our Tampa facility and we encourage you to visit anytime.  

**PLEASE NOTE A TABLE IS NOT INCLUDED
From the Manufacturer: 
The Zeiss IOLMaster 500 is the gold standard in optical biometry with more than 100 million successful IOL power calculations to date.
With the new version of the Zeiss IOLMaster 500, you get a piece of cutting-edge technology that points the way to the future of optical biometry.
IMPROVING REFRACTIVE OUTCOMES 
– Any intraocular lens calculation is only as reliable as the lens constant it is based on.
– More than 40,000 sets of patient data created with the Zeiss IOL Master are the basis of more than 200 optimized lens constants in the User Group for Laser Interference Biometry (ULIB) website absolutely unique in the industry. 
– Together with its one-of-a-kind distance independent telecentric keratometry and the exclusively integrated Holladay 2 formula, the gold standard in optical biometry helps you improve your refractive outcomes. 
EASE OF USE 
– A well-designed user interface, plausibility checks, distance-independent measurements, and an up to four times faster reading compared to other optical devices lead to a one-of-a-kind usability and reduced chair-time.
– A difference you, your team, and your patients will notice every day. 
MEASUREMENT RANGE 

– Axial length 14-38 mm 
– Corneal radii 5-10 mm 
– Anterior chamber depth 1.5-6.5 mm 
– White-to-white 8-16 mm 
DISPLAY SCALLING 

– Axial length 0.01 mm 
– Corneal radii 0.01 mm 
– Anterior chamber depth 0.01 mm 
– White-to-white 0.1 mm 
IOL CALCULATION FORMULAS 

– SRKII, SRK/ T, Holladay 1 and 2, Hoffer Q, Haigis 
– Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery 
– Haigis-L IOL calculation for eyes following myopic / hyperopic LASIK / PRK / LASIK surgery 
– Calculation of phakic anterior and posterior chamber implants 
– Optimization of IOL constants 
WE SHIP WORLDWIDE and have experience shipping to over 100 countries around the world.  Please email or message us for an international quote.
More photos available! Just ask.
Keep in mind we are not brokers. We are a full sales and service center. Each laser and piece of equipment we sell is hand picked, inspected, and tested by our technicians and engineers to ensure your order arrives in excellent condition both cosmetically and mechanically. Buy with confidence from Laser Locators!

Zeiss Visu 150 on an S7 Stand

Thank you for viewing our listing for this fully refurbished Zeiss Visu 150
This Ophthalmic Microscope has been fully tested and refurbished by our staff, then serviced by Prescott’s to ensure accuracy, quality and reliability.
We guarantee this Microscope to be working to specification and include a full warranty.

  • Excellent condition
  • Serviced and inspected by our in-house technicians
  • Includes Foot Switch and Manual
  • All optics cleaned
  • All functions tested
  • New Bulb

Perfect for an Ophthalmologist looking for a reliable standard microscope to be used for cataract surgery or any other ophthalmic procedure in our industry.
Please don’t hesitate to contact us at any time for further information or photos.
The OPMI Visu 150 Surgical Microscope and the S7 floor stand were developed together for the special demands of Ophthalmology. The system is controlled by a foot switch from which the surgeon may activate several motor driven functions.
WE SHIP WORLDWIDE and have experience shipping to over 100 countries around the world! Please email or message us for an international quote.
More photos available! Just ask.

Zeiss IOL Master Version 500 with Power Table, Printer, & amp; Calibration Test Eye

This unit has been fully tested, serviced and refurbished at our headquarters in Tampa, Florida. We also include a full warranty.  
 
Our trained technicians have tested and serviced this IOL 500 to ensure it is operating to the manufacturer’s specifications. The Zeiss system software is version 7.7 and the Holladay 2 Software is also active.     

The system is complete with the factory calibration test eye, refurbished Brother printer, original newer style Zeiss power table, operator’s manual, dust cover, and peripherals.  

Please feel free to contact us at any time for further information on this IOL 500. We ship to over 100 countries, the system is in stock here at our Tampa facility and we encourage you to visit anytime.  

From the Manufacturer: 
The Zeiss IOLMaster 500 is the gold standard in optical biometry with more than 100 million successful IOL power calculations to date.
With the new version of the Zeiss IOLMaster 500, you get a piece of cutting-edge technology that points the way to the future of optical biometry.
IMPROVING REFRACTIVE OUTCOMES 
– Any intraocular lens calculation is only as reliable as the lens constant it is based on.
– More than 40,000 sets of patient data created with the Zeiss IOL Master are the basis of more than 200 optimized lens constants in the User Group for Laser Interference Biometry (ULIB) website absolutely unique in the industry. 
– Together with its one-of-a-kind distance independent telecentric keratometry and the exclusively integrated Holladay 2 formula, the gold standard in optical biometry helps you improve your refractive outcomes. 
EASE OF USE 
– A well-designed user interface, plausibility checks, distance-independent measurements, and an up to four times faster reading compared to other optical devices lead to a one-of-a-kind usability and reduced chair-time.
– A difference you, your team, and your patients will notice every day. 

MEASUREMENT RANGE 
– Axial length 14-38 mm 
– Corneal radii 5-10 mm 
– Anterior chamber depth 1.5-6.5 mm 
– White-to-white 8-16 mm 

DISPLAY SCALLING 
– Axial length 0.01 mm 
– Corneal radii 0.01 mm 
– Anterior chamber depth 0.01 mm 
– White-to-white 0.1 mm 

IOL CALCULATION FORMULAS 
– SRKII, SRK/ T, Holladay 1 and 2, Hoffer Q, Haigis 
– Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery 
– Haigis-L IOL calculation for eyes following myopic / hyperopic LASIK / PRK / LASIK surgery 
– Calculation of phakic anterior and posterior chamber implants 
– Optimization of IOL constants 
WE SHIP WORLDWIDE and have experience shipping to over 100 countries around the world.  Please email or message us for an international quote.
More photos available! Just ask.

Carl Zeiss IOL Master Version 5.4 with Printer Manual & Calibration Test Eye

 This unit has been fully tested, serviced and refurbished at our headquarters in Tampa, Florida. We also include a full warranty.  
 
Our trained technicians have tested and serviced this IOL 5 to ensure it is operating to the manufacturer’s specifications. The Zeiss system software is version 5.4.4 and the operating system is Windows.     
 
*Table not included, please see other listings for unit with Manufacture table. 

KEY FEATURES 

– The IOLMaster from Carl Zeiss sets a new standard for highly accurate, 

precise measurements of all ocular characteristics necessary for IOL power 
calculations.
– The IOLMaster from Carl Zeiss is the world’s first instrument for the totally
non-contact measurement of all data required for the calculation of 
intraocular lenses.
– After more than ten years of clinical experience and ongoing product
enhancement, the IOLMaster is truly the Gold Standard in biometry.
 
Measuring ranges 

  • Axial length 14 – 40 mm 
  • Corneal radii 5 – 10 mm 
  • Depth of anterior chamber 1.5 – 6.5 mm 
  • White-to-white 8 – 16 mm 

Scaling of display 

  • Axial length 0.01 mm 
  • Corneal radii 0.01 mm 
  • Depth of anterior chamber 0.01 mm 
  • White-to-white 0.1 mm 


Formulas for IOL calculation

• SRK® II, SRK/T, Holladay, Hoffer Q, Haigis 
• Clinical history and contact lens fitting method for calculation of the corneal refractive power subsequent to refractive corneal surgery 
• Haigis-L for IOL calculation for eyes after myopic/hyperopic LASIK/PRK/LASEK 
• Calculation of phakic anterior and posterior chamber implants 
• Optimization of IOL constants Interfaces 
• Data interface for office management systems 
• Data export to CD-RW or USB storage media 
• Provision of data for Holladay IOL Consultant and HIC.SOAP Pro 
• Ethernet port for network connection and network printer 
• Compliance with HIPAA directive (USA only)in regard to user authentification and identification 

WE SHIP WORLDWIDE and have experience shipping to over 100 countries around the world. Please email or message us for an international quote.
More photos available! Just ask.
Keep in mind we are not brokers. We are a full sales and service center. Each laser and piece of equipment we sell is hand picked, inspected and tested by our technicians and engineers to ensure your order arrives in excellent condition both cosmetically and mechanically. Buy with confidence from Laser Locators!

Carl Zeiss Cirrus 500 Spectral Domain OCT HD with Windows Power Table Printer

Fully Refurbished Carl Zeiss Cirrus 500 Spectral Domain OCT HD with Windows, Power Table, Printer and Full Warranty

Excellent condition and completely refurbished by our in house Zeiss trained technician. 

Thank you for viewing our listing! This unit comes with Windows, printer, power table and all peripherals. 

Please see the photos for all activated licenses!

The Cirrus 500 is the current model offered by Zeiss, and they are very difficult to find on the used market. This OCT can be shipped almost anywhere in the world.

 Cirrus is the world’s best-selling spectral domain OCT system!

Visualization at the speed of Cirrus

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:

Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.

Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.

Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.

Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.

See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.

 Future-ready. Previously captured CIRRUS cubes can be analyzed using new analyses.

Tracking at the speed of Cirrus

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning

With FastTrac, scan at the highest resolution at the same location at each visit.

Assessment at the speed of Cirrus

Measurement centering with FoveaFinder and AutoCenter

On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.

AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.

Specifications

OCT Imaging

Methodology: Spectral domain OCT

Optical source: Superluminescent diode (SLD), 840 nm

Scan speed: 27K- 68K A-scans per second

A-scan: 2.0 mm (in tissue), 1024

Axial resolution: 5 μm (in tissue)

Transverse resolution: 15 μm (in tissue)

Fundus Imaging

Methodology: Line scanning opthalmoscope (LSO)

Live fundus image: During alignment and during OCT scan

Optical source: Superluminescent diode (SLD), 750 nm

Field of view: 36 degrees W x 30 degrees H

Frame rate: > 20 Hz

Transverse resolution: 25 μm (in tissue)

Iris Imaging

Methodology: CCD camera

Resolution: 1280 x 1024

More photos available! Just ask.
Keep in mind we are not brokers. We are a full sales and service center. Each laser and piece of equipment we sell is hand picked, inspected and tested by our technicians and engineers to ensure your order arrives in excellent condition both cosmetically and mechanically. Buy with confidence from Laser Locators!