Sonomed escalon, the brand of choice for ophthalmologists worldwide with products that continue to define the standards in diagnostic ultrasound.
Sonomed Escalon Accuracy
A combination of high frequency, low noise probes and proprietary algorithms enables scan capture immediately upon applanation along the visual axis with precise measurement of corneal thickness, acD, lens thickness, and axial length.
Sonomed Escalon Usability
intuitive interface, customized set-up, precise algorithms, and advanced hardware designs enable quick and easy examination of differ-ent eye types.
Sonomed Escalon Reliability
Consistent and accurate results, time after time, year after year, we build unparalleled quality into every ultrasound system. Sonomed escalon is still supporting instruments manu-factured over 20 years ago.
2-in-1 Features:
General
Modes
- 300A+ A-Scan Only
- 300AP+ A-Scan/Pachymeter
PacScan 300 Plus Features:
- High Contrast Color Touch Screen
- User Friendly Graphical Interface
- 5 Programmable User Profiles
- Scan Viewer Archiving Software
- USB Interface•SD Memory Card•Built-In Thermal Printer
- Storage Compartment
- Portable Design Weighing 6 lbs (2.7kg)
- Power Requirements:PacScan System: 100-240 VAC; 50/60 HzOptional Printer: 100-240 VAC; 50/60 H
300A+ A-Scan
Scan Modes:
- Direct Contact/Immersion
- 5 Examination Modes:CataractDense CataractAphakicPseudophakic (5 settings)4-Gate Manual
Measurements:
- ACD, Lens, Vitreous, Axial, Average Axial, Standard Deviation
- Individual Zone Velocities
- Automatic Sensing Algorithm
- Measure Review
- Auto-Calibration
Specifications:
- Clinical Accuracy: ±0.10mm
- Electrical Accuracy: ±0.023mm
- Lens Calculations in 0.25D Increments
- 10-Lens Database
Formulas:
- Refractive:BinkhorstRegression-IITheoretic/THolladayHoffer-QHaigis
- Post-Refractive:Latkany MyopicLatkany HyperopicAramberri Double-K
A-Scan Probe Styles:
- Standard A-Scan Probe for Hand-Held, Immersion, or Slit Lamp Mounted Application
- Soft-Touch A-Scan Probe for Hand-Held Use Minimizing Corneal Compression
Pachymeter (300AP+)
Scan Modes:
- Map 1: Single Point, Single-Scan
- Map 2: Single Point, Multi-Scan
- Map 3: 5 Points, Single-Scan
- Map 4: 5 Points, Multi-Scan
- CCT, IOP Correction
- Calibration
Measurements:
- Adjustable Corneal Velocity
- Automatic Sensing Algorithm
- Measure Review
- 64 Scans Averaged with Standard Deviation
- Internal Accuracy Test
- Auto Calibration
Specifications:
- Range: 125-1000 Microns
- Clinical Accuracy: ±5 Microns
- Electronic Accuracy: ±1 Microns
- 20MHz Direct Contact Probe
Pachymeter Probe Styles:
- 20 MHz Straight Pachymeter Probe for Use When Patient is in Sitting Position
- 20 MHz 45 Degree Angled Pachymeter Probe for Use When Patient is in Supine Position