A2000Pro A-Scan and IOL Calculator with 10MHz Probe

The PalmScan A2000 AScan Biometer is a unique device capable of performing both applanation as well as immersion biometry. It does both quickly and with extreme accuracy. The A2000 makes immersion biometry effortless through the use of the E-Z Tip Immersion Shell and the portable A-Scan ultrasound. With the A2000, time will no longer be a limiting factor in the office as the device takes only seconds to complete an immersion A-Scan, giving doctors quick results and leaving patients with no mess and no discomfort. With the A2000, it is not necessary for doctors to recline their patients or to juggle multiple tools in order to obtain an accurate immersion readings. Through the use of ultrasonic waves, the A2000 is able to quickly measure thicknesses of the anterior chamber, lens, and axial eye length to calculate the required IOL (intraocular lens) for a patient before surgery. PalmScan’s battery operated ultrasonic technology allows for measurements of even the densest cataractous eyes, giving you 100% patient coverage. Another feature of the A2000 A-Scan is the Contact/Applanation mode where the PalmScan utilizes our proven “Corneal Compression Detection” technique which warns the user of any corneal compression, preventing the user from taking inaccurate measurements.
Ophthalmic biometry has been made easy with the convenience and power of the PalmScan A2000, assuring a smooth and successful surgery for both patient and doctor.

Palm Scan A2000 A-Scan PRO has new and improved features to help your practice run more smoothly and efficiently. These new features have been received with the highest praise by our new customers and we invite you to experience it for yourself. The following new features have been added to the PalmScan PRO:

  • Additional internal rechargeable battery to supply probes that require higher power and extend operational time of the system.
  • You can also use an external charger while operating the device.  In addition, there are two ways to provide power, with a provided power supply and with a Micro USB charger.
  • The device also has a built in USB hub which allows up to 3 external connections to use different probes or with USB keyboard and mouse, or an external printer.

About A-Scan Biometry

A-Scan ultrasound biometry is routine type of diagnostic test used in ophthalmology. This equipment provides data on the length of the eye, which is a major determinant in common sight disorders. The most common use is to determine eye length for calculation of intraocular lens power. Briefly, the total refractive power of the emetropic eye is approximately 60. Of this power, the cornea provides roughly 40 diopters, and the crystalline lens 20 diopters. When a cataract is removed, the lens is replaced by an artificial lens implant.

Additional Features of PalmScan A2000 A-Scan Biometer

  • Independent study has proven this device to be as accurate as optical biometry
  • Applanation and immersion modes
  • Works with EZ-Tip Immersion soft shell for easiest immersion biometry
  • No need to recline your patients for immersion biometry with EZ-Tips
  • Compatible with traditional scleral immersion shells
  • Capable of measuring on very dense cataract eyes
  • Includes IOL calculator with modern formulas
  • Correction of keratometry for post Lasik eyes
  • Simple Interfaces with PalmScan K2000 Auto-Keratometer
  • EMR compatible with detailed PDF reports
  • Virtually unlimited storage of patient data
  • 10 MHz probe with fixation light

AP2000Pro Combination A-Scan and Surgical Pachymeter

PalmScan AP2000 AScan and Pachymeter system combines the of features of PalmScan A2000 AScan and P2000 Pachymeter into one, multi-function AScan and Pachymeter device that provides surgeons with state-of-the-art tools for success with cataract surgeries – particularly with premium IOL implants.
The A2000 AScan system has been clinically proven to be as accurate as laser interferometer systems. It is capable of penetrating the most dense cataract eyes and features both applanation (contact) and immersion settings. The system is capable of interfacing to the K2000 Auto-Keratometer device to create a truly comprehensive biometry solution for cataract surgeons. The built-in IOL calculator simplifies the IOL selection process with the ability to enter desired IOLs.
AScan features include:

  • Clinically proven to be as accurate as partial coherence interferometry
  • Contact and immersion captures
  • Compatible with EZ-Tip Immersion soft shell for easiest and cleanest immersion biometry
  • Perform immersion without having to recline your patient
  • Compatible with traditional hard immersion shells
  • Dense Cataract Penetration – not limited by the density of the cataract lens
  • Built-In IOL calculator with advance formulas
  • Post Lasik correction of keratometry
  • EMR compatible
  • Unlimited storage of patient data
  • Generate comprehensive PDF reports
  • 10 MHz probe with fixation light

P2000Pro Surgical Pachymeter w/50MHz Probe

The PalmScan P2000 Pachymeter is an indispensable tool for corneal measurements. It gives the user the ability to quickly and accurately measure at any location on the cornea. Unlike other pachymeters in the market today, PalmScan allows the users to verify the accuracy of measurements by displaying the measured echogram of the cornea in order to confirm the validity of the measurement.

With a 3 micron measurement accuracy, PalmScan P2000 is the most accurate device available today. It comes with a high frequency, high bandwidth 50 MHz probe which sets it apart from all other devices in its class and allow for measurements of ultra thin structures as well as ability to measure on diseased  corneas.

In the CCT mode, P2000 Pachymeter allows users to accurately measure the corneal thickness and calculate the adjusted IOP value based on the measurement. In addition, In the CMAP mode, a corneal thickness map can be generated based on the measurement of the cornea at 17 various locations. The measurements for left and right eye are stored separately in a convenient patient database.

This pachymeter system also has the ability to create a PDF report of the measurements and calculations and to send these reports wirelessly to a printer or to a EMR system.

Ability to measure corneas through the single use Pachy Tip Cover is another exceptional feature of the PalmScan P2000 Pachymeter. With the Pachy Tip Covers you can make most accurate measurements in a surgical setting without compromising the patient with cross contamination.

 PalmScan P2000 PRO has new and improved features to help your practice run more smoothly and efficiently. These new features have been received with the highest praise by our new customers and we invite you to experience it for yourself. The following new features have been added to the PalmScan PRO:

  • Additional internal rechargeable battery to supply probes that require higher power and extend operational time of the system.
  • You can also use an external charger while operating the device.  In addition, there are two ways to provide power, with a provided power supply and with a Micro USB charger.
  • The device also has a built in USB hub which allows up to 3 external connections to use different probes or with USB keyboard and mouse, or an external printer.

Also available as part of the PalmScan AP2000 A-Scan and Pachymeter system.

P2000 Pachymeter Features

Central and Peripheral corneal Pachymetry
50 MHz Probe (highest in the market)
264 MHz sampling (highest in the market)
Tip Cover Pachymetry
Dry Bed Measurements
Corneal Waveform Technology
Highest Accuracy
Fast measurements
EMR compatible
Generates PDF Pachymetry reports

A2000T A-Scan and IOL Calculator with 10MHz Probe

Significant Breakthrough in Immersion A-scan Biometry

Perform Immersion A-Scan in a few seconds without having to recline your patients

The PalmScan A2000 A-Scan is an exceptional device able to perform both applanation and immersion biometry. It does both rapidly and with high accuracy. The A2000 makes immersion biometry simple through the use of the E-Z Tip Immersion Shell and the portable A-Scan ultrasound. With the A2000, time will no longer be a restraining factor in the office as the device takes only seconds to complete an immersion A-Scan. It gives doctors rapid outcomes and has the patient walking out the door looking better than before! With the A2000, it is not necessary for doctors to recline their patients or to juggle multiple tools in order to obtain an accurate immersion reading. Through the use of ultrasonic waves, the A2000 is able to quickly measure thicknesses of the anterior chamber, lens, and axial eye length to calculate the required IOL (intraocular lens) for a patient before surgery. PalmScan’s battery operated ultrasonic technology allows for measurements of even the densest cataractous eyes, giving you 100% patient coverage. Another feature of the A2000 is the Contact/Applanation mode where the PalmScan utilizes our proven “Corneal Compression Detection” technique which warns the user of any corneal compression, preventing the user from taking inaccurate measurements.
Ophthalmic biometry has been made easy with the performance of the PalmScan A2000, assuring a smooth and successful surgery for both patient and doctor.

PalmScan A2000T features include:

  • Independently proven to be as accurate as optical biometry
  • Applanation and immersion modes of operation
  • Works with EZ-Tip Immersion soft shell for easiest immersion biometry
  • No need to recline your pateints for immersion biometry
  • Compatible with traditional scleral immersion shells
  • Capable of measuring on extreemly dense cataract eyes
  • Includes IOL calculator with modern formulas
  • Correction of keratometry for post Lasik eyes
  • EMR compatible with detailed PDF reports
  • Large patient database
  • 10 MHz probe with blinking fixation light
  • Tablet PC is included
  • One Year Warranty

P2000T Surgical Pachymeter w/50MHz Probe

When microns matter, PalmScan Delivers

The PalmScan P2000 Pachymeter is an indispensable tool for corneal measurements. It gives the user the ability to quickly and accurately measure at any location on the cornea. Unlike other pachymeters in the market today, PalmScan allows the users to verify the accuracy of measurements by displaying the measured echogram of the cornea in order to confirm the validity of the measurement.

With a 3 micron measurement accuracy, PalmScan P2000 is the most accurate device available today. It comes with a high frequency, high bandwidth 50 MHz probe which sets it apart from all other devices in its class and allow for measurements of ultra thin structures as well as ability to measure on diseased  corneas.

In the CCT mode, P2000 Pachymeter allows users to accurately measure the corneal thickness and calculate the adjusted IOP value based on the measurement. In addition, In the CMAP mode, a corneal thickness map can be generated based on the measurement of the cornea at 17 various locations. The measurements for left and right eye are stored separately in a convenient patient database.

This pachymeter system also has the ability to create a PDF report of the measurements and calculations and to send these reports wirelessly to a printer or to a EMR system.

Ability to measure corneas through the single use Pachy Tip Cover is another exceptional feature of the PalmScan P2000 Pachymeter. With the Pachy Tip Covers you can make most accurate measurements in a surgical setting without compromising the patient with cross contamination.

P2000 Pachymeter Features

Central and Peripheral corneal Pachymetry
50 MHz Probe (highest on the market)
264 MHz sampling (highest on the market)
Tip Cover Pachymetry
Dry Bed Measurements
Corneal Waveform Technology
Highest Accuracy
Fast measurements
EMR compatible
Generates PDF Pachymetry reports